ALIPLAST - GENESIS 75

ALIPLAST - GENESIS 75

Provider: ALIPLAST

The modern system with a construction depth of 75 mm and optimal thermal insulation.
Genesis 75 is a system used for the construction of window and door structures in both public and residential buildings.
✔ The Genesis 75 system incorporates modern insulating materials recently launched on the market; in addition to a conventional central seal, a supplementary thermal seal has also been developed. With this solution, very good water tightness and air permeability can be achieved.
✔ The Genesis 75 system sets a new standard for thermal performance in windows, with the highest ergonomics of use and modern profile aesthetics.
✔ Maximum glass package installation possibility: 59 mm. View details

  • Contact us now for a personalized offer and free consultation!

  • A wide range of available colors – RAL palette (Qualicoat 1518), structured colors, Aliplast Wood Color Effect wood imitation, Aliplast Loft View – stone imitation (Qualideco PL-0001), anodized colors (Qualanod 1808), and bi-color options.

TECHNICAL SPECIFICATION

SYSTEM MATERIAL

DEPTH OF FRAME

DEPTH OF LEAF

GLAZING RANGE ACOUSTIC TYPE OF WINDOWS TYPE OF DOORS
GN 75 window aluminium/ thermal insulation 75 mm 84 mm fix 1 - 56 mm / 9-65 mm 45 (-1,-3) dB fix, turn-only, tilt and turn -
GN 75 door aluminium/ thermal insulation 75 mm 75 mm 1 - 59 mm 44 (-1,-4) dB - single and double doors, outside and inside opening, panic doors

PERFORMANCE

SYSTEM THERMAL INSULATION UF*

AIR PERMEABILITY

WINDLOAD RESISTANCE

WATERTIGHTNESS
GN 75 window Uf from 1,35 W/m2K Class 4; PN-EN 12207  E2400 (2400 Pa); PN-EN 12210 E1800 (1800Pa)/E1950*(E1950 Pa); PN-EN 12208
GN 75 i+ window Uf from 0,76 W/m2K Class 4; PN-EN 12207 E2400 (2400 Pa); PN-EN 12210 E1800 (1800Pa)/E1950*(E1950 Pa); PN-EN 12208
GN 75 door  Uf from 1,625 W/m2K Class 4; PN-EN 12207  C5 (2000Pa); PN-EN 12210 E1200 (1200Pa); PN-EN 12208
GN 75 i+ door Uf from 1,195 W/m2K Class 4; PN-EN 12207  C5 (2000Pa); PN-EN 12210 E1200 (1200Pa); PN-EN 12208

*Thermal insulation is dependent on a combination of profiles and thickness of the filling

*A value of 1950 Pa was obtained during testing

By using our services, you agree that we use cookies and other similar technologies in order to improve and customize our content, for the purpose of analyzing traffic, providing advertising and anti-spam and anti-malware protection, as well as and against unauthorized use. For more details, please refer to the Privacy Policy and the Cookies Policy.